Home > Products > NeuroVision AMT: the cerebral aneurysm universal measurement tool
NeuroVision AMT: the cerebral aneurysm universal measurement tool
An Automatic, easy to use, universal measurement software tool using DICOM data on PC
NeuroVision AMT Profile
NeuroVision AMT automatically measures the volume and dimensions (Height x Width X Neck) of the cerebral aneurysm with ease to use, and to support the embolization planning and its uniform evaluation before and after the treatment.
The measurement itself is completed within TWO (2) minuets in average.
NeuroVision AMT is co-developed with The Jikei University School of Medicine ( Dr. Murayama ).
| Features |
1. Easy to measure and provide an uniform evaluation method for Volume and dimensions (Height x Width X Neck) of aneurysm - The automatic measurement is done by pointing the aneurysm and its mother blood vessel
2. Independent volume calculations for each aneurysm - Higher accuracy than conventional approximation method by sphere model
3. A manual measurement mode is also provided for a complicated shape.
|
|
Measurement Process
1. Reading DICOM data / Choosing the Region of interest
The Area including aneurysm is taken out by 3D bounding box, on the visualized data of DICOM data.
2. The extraction of the aneurysm
Depending on the shape of the aneurysm, either the automatic or manual method is chosen.
The automatic methods include such modes as Profile, Center Half Value, Discriminant Analysis.
3. Aneurysm and the mother blood vessel
All needed are One-point-click on aneurysm (White) with Two-point-clicks on the mother blood vessel (Blue and Green), followed by Enter key.
4. Measurement: Volume , Neck, Height, Width
Measurement results: Volume , Neck, Height, Width, appeared on the aneurysm
5. Volume embolization rate (VER)
Volume embolization rate (VER)* is automatically calculated by inputting the coil data.
VER data is also output to CSV.
*VER=Coil Volume over Aneurysm
6. Coil information and its compositing rate
Compositing ratio of GDC and Matrix Coil (Fig. Below/Right)
Ratio of Polymer and Bare of Matrix coil (Fig. Below/ Left)
Price and Support
| Product | Price | Note |
| NeuroVision AMT | 120,000 JPY (Japanese Yen) | - Annual License - PC is not included. - Tech Support by e-mail |
| Recommended Platform Requirement |
- OS: Windows XP / Vista
- CPU: Intel Core2 Duo min.
- Memory: 2GB Min.
- Display Resolution: 1024 x 768 min.
|
| Catalogue |
| NeuroVision AMT(PDF: 3.37MB) |
| Inquiry |
CYBERNET SYSTEMS CO.,LTD.
Advanced Solution Division
Visualization Department
E-mail: med-info@cybernet.co.jp
|